• Product Search
    Enter a part number or product name to perform a quick search of results with your search term...
    Search Term:
    Results
    • Cart

    Complete RDE System Bundle: WaveDriver 40, WaveVortex 10, E5TQ Series RDE

    Part Number
    [WD40-WV10-RDE-E5TQ]

    The best way to work with a Pine Research Rotating Disk Electrode (RDE) system is to pair it with a Pine Research electrochemical workstation.  This bundle gets you started with a ChangeDisk RDE tip, an interchangeable glassy carbon disk insert, a WaveDriver® series bipotentiostat/galvanostat, and a WaveVortex® electrode rotator. Under the control of our powerful AfterMath® software package, the WaveDriver 40 DC bipotentiostat/galvanostat is capable of performing a wide range of DC electroanalytical techniques, including several Rotating Disk Electrode (RDE) methods.

    [alert color=”violet” icon=”bullhorn”]Every purchase of a Pine Research potentiostat and rotating electrode bundle includes a free one-hour online training session! Contact Pine Research now (click here) to learn more and to schedule your training session.[/alert]

    The compact WaveVortex 10 Electrode Rotator lets you get started immediately with RDE experiments.  Later, when you are ready to expand your research to include dual working electrode techniques, simply thread an RRDE tip on to the rotator and connect the ring electrode to the second working electrode connection on the bipotentiostat.  This RDE start-up bundle includes the following principal items along with compatible cables and accessories:

    • WaveDriver 40 DC Bipotentiostat/Galvanostat
    • WaveVortex 10 Electrode Rotator, ChangeDisk RDE tip, and glassy carbon disk insert
    • Pine Research AfterMath Software
    • Jacketed RDE Cell (glass) with Pt Counter and Ag/AgCl Reference Electrode

    Additional information is provided under the “Description” tab below.

    Product Bundle
    This is a product bundle. Product bundles combine compatible products together for easier purchasing and confidence. You can view the bundles that include this product in the tab below.

    The best way to work with a Pine Research Rotating Disk Electrode (RDE) system is to pair it with a Pine Research electrochemical workstation.  This bundle gets you started with a ChangeDisk RDE tip, an interchangeable glassy carbon disk insert, a WaveDriver® series bipotentiostat/galvanostat, and a WaveVortex® electrode rotator. Under the control of our powerful AfterMath® software package, the WaveDriver 40 DC bipotentiostat/galvanostat is capable of performing a wide range of DC electroanalytical techniques, including several Rotating Disk Electrode (RDE) methods.

    [alert color=”violet” icon=”bullhorn”]Every purchase of a Pine Research potentiostat and rotating electrode bundle includes a free one-hour online training session! Contact Pine Research now (click here) to learn more and to schedule your training session.[/alert]

    The compact WaveVortex 10 Electrode Rotator lets you get started immediately with RDE experiments.  Later, when you are ready to expand your research to include dual working electrode techniques, simply thread an RRDE tip on to the rotator and connect the ring electrode to the second working electrode connection on the bipotentiostat.  This RDE start-up bundle includes the following principal items along with compatible cables and accessories:

    • WaveDriver 40 DC Bipotentiostat/Galvanostat
    • WaveVortex 10 Electrode Rotator, ChangeDisk RDE tip, and glassy carbon disk insert
    • Pine Research AfterMath Software
    • Jacketed RDE Cell (glass) with Pt Counter and Ag/AgCl Reference Electrode

    Additional information is provided under the “Description” tab below.

    Components below showing require a selection. Components showing are optional, and do not require a selection.

    Bundle Customizer

    Toggle each component below and make your selection. Once all required selections have been made, the total price and add to cart button will display at the end of the components list.

    More Detail
    Bundle Products
    Specifications
    [alert color="green" icon="info-circle"]This bundle includes an E5TQ series ChangeDisk RDE tip with an interchangeable glassy carbon disk insert. As your research grows, you can expand your rotating electrode collection to include a wide variety of additional RDE and RRDE tip designs that are compatible with the WaveVortex 10 rotator.[/alert]

    The WaveDriver 40 DC Bipotentiostat/Galvanostat is an affordable benchtop bipotentiostat/galvanostat system capable of performing a wide variety of single and dual working electrode DC electroanalytical techniques. Unlike many other bipotentiostat offerings on the market, the fundamental design of the WaveDriver 40 makes it just as easy for you to use two working electrodes in an electrochemical cell as it is to use just one working electrode.

    True Integrated Bipotentiostat. From the software to the cell cable design, everything about the WaveDriver 40 bipotentiostat makes working with dual working electrode configurations as straightforward as possible: no messy inter-channel connections are required, and no additional cell cables or adapters are required. The WaveDriver 40 connects to your laptop or PC via a standard USB cable and is controlled by our powerful AfterMath software. The software user interface is designed with two working electrodes in mind, so entering experimental parameters for dual-electrode techniques is quick-and-easy.

    [call_to_action color="blue" button_text="WaveDriver 200 Bipotentiostat" button_url="https://dev-tim.pineresearch.com/devnewtheme/shop/potentiostats/wavedriver-series/wavedriver200-bundles/"]If you also need to perform Electrochemical Impedance Spectroscopy (EIS), please choose one of our WaveDriver 200 bundles instead.[/call_to_action]Applications. The WaveDriver 40 finds use in academic and industrial research laboratories around the world and across a wide variety of applications. The instrument offers a large range of accessible current ranges (±100 nA up to ±1 A) and potential ranges (±2.5V up to ±15 V) along with advanced filtering and iR compensation. Back panel connections allow rotation rate control when performing voltammetry using a Rotating Disk Electrode (RDE), Rotating Ring-Disk Electrode (RRDE), or Rotating Cylinder Electrode (RCE). Additional input/output and timing connections permit the WaveDriver to control third-party instrumentation in applications such as UV/Visible Spectroelectrochemistry.

    Cost Effective. Take a look around at similar bipotentiostat/galvanostat systems and you will have a difficult time finding one with comparable specifications and capabilities at the same modest price point. Designed with the everyday user in mind, the specifications for the WaveDriver 40 bipotentiostat are broad enough to permit you to perform a wide range of routine electrochemical techniques but also prudently chosen to allow for a simple and affordable design. Popular and common techniques such as cyclic voltammetry, bulk electrolysis, differential pulse voltammetry, square wave and pulse voltammetry, battery charge/discharge sequences, corrosion techniques (such as linear polarization resistance), chronoamperometry, and chronopotentiometry are easily configured and executed using our AfterMath software package.

    What makes the WaveDriver 40 bipotentiostat even more powerful? Combining it with a precision electrode rotator manufactured by Pine Research...

    MAXIMUM ROTATION RATE: Each electrode tip model used with the WaveVortex 10 rotator has a maximum rotation rate. Do not the exceed maximum rotation rate when working with rotating electrodes.

    The WaveVortex 10 Electrode Rotator is designed to suit the needs of those looking to perform rotating disk (RDE) and rotating ring-disk (RRDE) electrode experiments with limited lab space.  This small footprint rotator is compatible with all 15 mm OD RDE/RRDE electrodes manufactured by Pine Research, along with many of our cells, glassware, and accessories.

    The control box, motor, shaft, and enclosure are all fixed into one convenient unit, making the WaveVortex compact and portable.  The rotation rate can be manually adjusted on the front panel and monitored on the digital display.  Alternately, a potentiostat can control the rotation rate using an appropriate rate control cable.

    Electrode connections are made to the rotating shaft using silver-carbon brushes.  There are two contacts - the red is for the disk, and the blue is for the ring.

    [call_to_action color="red" button_text="Pine Research YouTube " button_icon="youtube-play" button_url="https://www.youtube.com/channel/UCkaSux3EzBER0CU8P_9IOsw"] Visit our YouTube channel for helpful instructional videos regarding the use and maintenance of this and many other Pine Research products. [/call_to_action]
    Complete RDE System Bundle: WaveDriver 40, WaveVortex 10, E5TQ Series RDE is sold as a product bundle. Product bundles combine multiple products into one purchase. For details or to purchase additional items, visit the product page for any item in the bundle below.
    Qty
    Image
    Product Name
    Part #
    1
    WaveDriver 40 Electrochemical Workstation
    AFP4
    1
    WaveVortex 10 Electrode Rotator
    AF01WV10
    1
    Rotation Rate Control Interface Cable, for WaveVortex 10 and MSR evo Rotators, WaveDriver Series and WaveNow XV
    AKCABLE7-03
    1
    E5TQ Series ChangeDisk Rotating Disk Electrode, PEEK
    AFE5TQ050PK
    1
    RDE/RRDE Disk Insert, 5 mm OD x 4 mm thick, Glassy Carbon (GC)
    AFED050P040GC
    1
    E5/E6 Series ChangeDisk Electrode Toolkit
    AFE6K050
    1
    Counter Electrode Assembly, Platinum (Pt), 14/20
    AFCTR5
    1
    Reference Electrode, Silver/Silver Chloride, Single Junction
    RREF0021
    1
    Rotating Disk/Ring-Disk Cell Kit, Standard Volume, Water Jacket
    AKCELL3
    1
    Bearing Assembly, Gas-Purged, for AFE6MB/AFE9MBA Shaft, PEEK, with 24/25 Taper
    AC01TPA6M
    1
    Electrode Polishing Kit
    AKPOLISH
    Complete RDE System Bundle: WaveDriver 40, WaveVortex 10, E5TQ Series RDE is sold as a product bundle. The data below aggregates the specifications for each product contained within the bundle..
    Complete RDE System Bundle: WaveDriver 40, WaveVortex 10, E5TQ Series RDE
    Product Bundles
    Product bundle
    Bundle includes
    Counter electrode, Electrochemical cell, Electrochemical workstation, Electrode rotator, Reference electrode, Rotating disk working electrode
    Bundle application
    General electrochemistry, Rotating Disk (RDE)
    Bundled electrode rotator
    WaveVortex 10
    Bundled electrochemical workstation
    WaveDriver 40
    WaveDriver 40 Electrochemical Workstation
    Electrochemical Workstations
    Electrode Connections
    Reference electrode
    Sense line with driven shield
    Counter electrode
    Drive line with grounded shield
    Working electrode channels
    Working electrode #1 (WK1)
    Separate sense and drive lines, each with driven shield (current measurement via passive shunt)
    Working electrode #2 (WK2)
    N/A, Separate sense and drive lines, each with driven shield (current measurement via transimpedance amplifier)
    Ground Connections
    DC common (signal)
    The DC Common is isolated from the USB port, the instrument chassis and earth ground. The DC Common is accessible via a banana binding post (black) on the back panel.
    Chassis terminal
    The instrument chassis terminal is accessible via a banana binding post (metal) on the back panel. The GRAY banana plug on the cell cable also provides a chassis connection.
    Earth
    No direct connection to earth ground is provided.
    Measured Current (Potentiostatic Mode)
    Current ranges (measured)
    Current resolution at each range (measured)
    31.3 µA, 3.13 µA, 313 nA, 31.3 nA, 3.13 nA, 313 pA, 31.3 pA, 3.13 pA
    Autoranging
    Yes
    Practical current range
    20 pA to 1 A
    DC accuracy (current, measured)
    ±0.2% of setting; ±0.05% of range
    DC leakage current
    <10 pA at 25°C
    AC accuracy (measured)
    N/A
    AC leakage current
    N/A
    ADC input
    16 bits
    Filters (for DC Experiments)
    10 kHz, 100 kHz, 1 kHz, 100 Hz, 30 Hz, 10 Hz
    Applied Current (Galvanostatic Mode)
    Current resolution at each range (applied)
    31.3 µA, 3.13 µA, 313 nA, 31.3 nA, 3.13 nA, 313 pA, 31.3 pA, 3.13 pA
    DC accuracy (current, applied)
    ±0.2% of setting; ±0.05% of range
    DAC output (current)
    16 bits
    Power Amplifier (Counter Electrode Amplifier)
    Output current
    ±1 A (maximum)
    Short circuit current limit
    10 mA - 100 nA ranges: <200 mA, 1A, 100 mA ranges: <1.3 A
    Compliance voltage
    Bandwidth
    >2.5 MHz (on fastest speed setting)
    Noise and ripple
    <35 µV RMS in 2 MHz bandwidth
    Slew rate/rise time
    10 V/µs (on fastest speed setting)
    Electrometer (Reference Electrode Amplifier)
    Input impedance
    >10¹³ in parallel with <10 pF
    Input current
    <10 pA leakage/bias current at 25°C
    CMRR
    >100 dB, 0 - 1 kHz, >74 dB at 10 kHz
    Electrometer bandwidth
    >15 MHz (3 dB)
    Measured Potential
    Potential ranges (measured)
    Potential resolution at each range (measured)
    313 µV per ADC bit, 469 µV per ADC bit, 78 µV per ADC bit
    DC accuracy (potential, measured)
    ±0.2% of setting; ±0.05% of range
    ADC output
    16 bits
    Filters (for DC Experiments)
    10 kHz, 100 kHz, 1 kHz, 100 Hz, 30 Hz, 10 Hz
    Applied Potential (Potentiostatic Mode)
    Potential ranges (applied)
    Potential resolution at each range (applied)
    313 µV per DAC bit, 469 µV per DAC bit, 78 µV per DAC bit
    DC accuracy (potential, applied)
    ±0.2% of setting; ±0.05% of range
    DAC output (potential)
    16 bits
    CV sweep rate (minimum)
    CV sweep rate (maximum)
    Data Acquisition (for DC Experiments)
    Clock resolution
    10 ns (minimum time base)
    Point interval
    Synchronization
    Simultaneous current and potential input
    Raw point total
    <10 million per experiment
    Electrochemical Impedance Spectroscopy (EIS)
    EIS capable
    EIS frequency range
    EIS frequency resolution
    N/A
    EIS frequency stability
    N/A
    Modes
    N/A
    Voltage excitation setpoint
    N/A
    Current excitation setpoint
    N/A
    Frequency sweeping
    N/A
    EIS accuracy
    N/A
    Rotator Control Connections
    Rotator connector A
    7-pin mini circular DIN includes analog and digital signal grounds, digital rotator enable signal (+15 V max), auxiliary digital output signal, and analog rotation rate control signal
    Rotator connector B
    3-pin connector includes analog signal ground, digital rotator enable signal (+15 V max), and analog rotation rate control signal
    Rate control signal
    ±10 V, ±2.5 V
    Digital enable signal
    Open drain with 4.7 kΩ pull up to +5 V (TTL compatible)
    Accessories
    Dummy cell
    External dummy cell included
    Cell cable
    Combination D-SUB connector to multiple banana plugs via shielded coaxial cables (included)
    Auxiliary Connections
    Connector C
    9-pin DSUB connector that includes DC Common, two digital output signals, and two digital input signals
    Trigger input
    BNC female, TTL compatible
    Trigger output
    BNC female, TTL compatible
    Potential (E1) output
    BNC female, ±15 V, ±10 V, ±2.5 V output, ±0.5% accuracy
    Current (I1) output
    BNC female, ±10 V output, scaled to current range, ±0.5% accuracy
    Potential (E2) output
    BNC female, ±15 V, ±10 V, ±2.5 V output, ±0.5% accuracy
    Current (I2) output
    BNC female, ±10 V output, scaled to current range, ±0.5% accuracy
    Auxiliary analog input
    BNC female, ±10 V differential input, 313 µV resolution, 0.2% accuracy (available when second working electrode not in use)
    Auxiliary analog output
    BNC female, ±10 V bipolar output, 313 µV resolution, 0.2% accuracy (available when second working electrode not in use)
    WK1 input
    BNC female, ±10V differential input, 20 kΩ impedance, ±0.5% accuracy; allows external waveform to be summed directly to the working electrode excitation signal
    WK2 input
    BNC female, ±10V differential input, 20 kΩ impedance, ±0.5% accuracy; allows external waveform to be summed directly to the working electrode excitation signal
    General
    Power input
    24 VDC (±5%), 5.0 A (low voltage DC device)
    Power supply input
    100 - 240 VAC, 1.4 - 0.7 A, 50 - 60 Hz
    Power supply output
    24 VDC, 5.0 A power supply (included) has a C14 type input connector
    Power cord
    Various international cables sold separately (C13 type)
    LED indicators
    Power, USB, and status
    Instrument dimensions
    160 × 324 × 255 mm (6.3 × 12.75 × 10.0 in)
    Workstation shipping dimensions
    254 × 356 × 457 mm (10 × 14 × 18 in)
    Instrument weight
    4.6 kg (10.2 lb)
    Workstation shipping weight
    7.7 kg (17 lb)
    Temperature range
    10°C - 40°C
    Humidity range
    80% RH maximum, non-condensing
    Communication
    Interface
    Wireless capable
    WaveVortex 10 Electrode Rotator
    Electrode Rotator
    Motor
    Motor Bandwidth
    Undetermined
    Control method
    Closed loop servo-system (PWM); temperature-compensated tachometer mounted on motor shaft
    Maximum continuous torque
    Motor power
    Motor protection
    Motor current is electronically limited
    Motor type
    Permanent Magnet
    Slew Rate
    Undetermined
    Electrical
    Rotator AC power input
    100 - 240 VAC, ±10%, 50/60 Hz, 2 A
    Rotator DC power supply
    24 VDC, 1.5 A (included)
    Power switch location
    Side of unit
    Grounding
    Rotator chassis terminal
    Metal banana jack on motor unit, Second connection provided on external I/O port
    DC common (analog ground)
    Connection provided on external I/O port
    Rotator earth ground
    No direct connection available
    Rotation Rate
    Enclosure interlock
    Interlock prevents rotation when enclosure window is in raised position. Front panel LED indicates enclosure interlock state.
    Motor stop connection
    Optional digital motor stop input signal on external I/O port, available TTL logic: active high or active low, jumper selectable, front panel LED indicates when external motor stop is active
    External rate control
    Optional rate control via input signal on external I/O port; available control ratios: 1, 2, or 4 RPM/mV, jumper selectable
    Rate display
    4 digit display indicates rotation rate (RPM)
    Start/stop (front panel)
    Push-button toggle on front panel with LED indicators for “pause” and “run”
    Physical
    Electronics cabinet material
    Black powder-coated aluminum
    Enclosure base and sides materials
    Black high-density polyethylene (PE)
    Enclosure window material
    Clear polycarbonate (PC)
    Operating temperature
    10 °C - 40 °C (50 °F - 104 °F)
    Rotator shipping weight
    Rotator shipping dimensions
    Safety & Environmental
    Rotator RoHS compliant
    Yes
    Rotator safety certification
    Compatibility
    Rotation Rate Control Interface Cable, for WaveVortex 10 and MSR evo Rotators, WaveDriver Series and WaveNow XV
    Cables
    Cable type
    Interface, Signal
    Cable terminal A type
    Plug, Terminal Block, Green, 3-pin
    Cable terminal B type
    Plug, Terminal Block, Green, 8-pin
    Cable length
    3 ft
    Cable color
    Gray
    Cable instrument compatibility
    MSR evo electrode rotator, WaveDriver series electrochemical workstation, WaveNow XV electrochemical workstation, WaveVortex 10 electrode rotator
    E5TQ Series ChangeDisk Rotating Disk Electrode, PEEK
    Working Electrodes
    General
    Electrode series
    Thermal stability range
    10°C - 80°C
    Electrode use/application
    Electrode Tips
    Tip maximum rotation rate
    Maximum immersion depth
    12 mm
    Tip shroud material
    Tip shroud diameter
    15 mm
    Tip shroud length
    25.4 mm
    Tip length (overall)
    49 mm
    RDE/RRDE Disk Insert, 5 mm OD x 4 mm thick, Glassy Carbon (GC)
    Working Electrodes
    Rotating Electrodes
    Rotating electrode type
    Disk Electrodes
    Disk material
    Disk finish
    Mirror Polish
    Disk diameter
    Disk thickness
    Disk type
    Insert (no electrode body)
    Electrode Tip Compatibility
    Reference Electrode, Silver/Silver Chloride, Single Junction
    Reference Electrodes
    Reference chemistry
    Standard potential
    Reference size type
    Reference electrode body diameter
    Reference electrode length
    Body material
    borosilicate glass
    Reference frit material
    External fill solution
    Refillable
    Typical variance
    ±3 - 5 mV
    Typical input impedance
    < 10 kΩ
    Reference electrode connection style
    1.6 mm OD x 8.5 mm long brass pin
    Rotating Disk/Ring-Disk Cell Kit, Standard Volume, Water Jacket
    Electrochemical Cell
    14/20 Ports
    24/25 Ports
    Cell material
    Cell volume (overall, max)
    Cell water jacket
    Cell diameter
    100 mm (with jacket)
    Cell height
    108 mm