    WavePico Wireless Electrochemical Workstation

    Part Number
    AFTP5

    This newest addition to our WaveNow® electrochemical workstation series lets you enjoy the freedom of controlling your electrochemical experiments wirelessly! This system also offers the lowest current resolution offered by Pine Research (Practical range lower current is 40 fA), making the WavePico Wireless you trusted workstation for low current measurements, such as what what may be measured when developing biosensors. The WavePico Wireless electrochemical workstation is a potentiostat and galvanostat that gives you portability and access to remote lab spaces without creating a cabling problem. This is the perfect system for use in a glovebox – simply put the entire instrument into the glovebox along with your electrochemical cell and conduct your air-sensitive voltammetry experiments from any nearby computer.

    Under the control of our powerful AfterMath Blue® software package, the WavePico Wireless is capable of performing a wide variety of popular DC electroanalytical techniques. Start enjoying the benefits of wireless control and ultra-low current measurements today!

    Out of stock

    This newest addition to our WaveNow® electrochemical workstation series lets you enjoy the freedom of controlling your electrochemical experiments wirelessly! This system also offers the lowest current resolution offered by Pine Research (Practical range lower current is 40 fA), making the WavePico Wireless you trusted workstation for low current measurements, such as what what may be measured when developing biosensors. The WavePico Wireless electrochemical workstation is a potentiostat and galvanostat that gives you portability and access to remote lab spaces without creating a cabling problem. This is the perfect system for use in a glovebox – simply put the entire instrument into the glovebox along with your electrochemical cell and conduct your air-sensitive voltammetry experiments from any nearby computer.

    Under the control of our powerful AfterMath Blue® software package, the WavePico Wireless is capable of performing a wide variety of popular DC electroanalytical techniques. Start enjoying the benefits of wireless control and ultra-low current measurements today!

    Components below showing require a selection. Components showing are optional, and do not require a selection.

    Bundle Customizer

    Toggle each component below and make your selection. Once all required selections have been made, the total price and add to cart button will display at the end of the components list.

    Specifications
    Electrochemical Workstations
    Electrode Connections
    Reference electrode
    Sense line with driven shield
    Counter electrode
    Drive line with grounded shield
    Working electrode channels
    Working electrode #1 (WK1)
    Separate sense and drive lines, each with driven shield (current measurement via passive shunt)
    Working electrode #2 (WK2)
    N/A
    Ground Connections
    DC common (signal)
    The DC Common is isolated from the USB port, the instrument chassis, and earth ground. The DC Common is accessible via the Control Port on the back panel.
    Chassis terminal
    The instrument chassis terminal is accessible via a banana binding post (metal) on the back panel. The GRAY banana plug on the cell cable also provides a chassis connection.
    Earth
    No direct connection to earth ground is provided.
    Measured Current (Potentiostatic Mode)
    Current ranges (measured)
    Current resolution at each range (measured)
    47 nA, 1.57 nA, 47 fA, 1.57 fA, 47 pA, 1.57 pA
    Autoranging
    Yes
    Practical current range
    40 fA to 1.5 mA
    DC accuracy (current, measured)
    ±0.2% of setting plus ±0.05% of upper five current ranges; ±0.5% of 50 pA range with ±1 pA offset
    DC leakage current
    < 20 fA at 0 VDC, < 130 fA at 5 VDC
    AC accuracy (measured)
    N/A
    AC leakage current
    N/A
    ADC input
    16 bits
    Filters (for DC Experiments)
    1 kHz, 12 Hz
    Applied Current (Galvanostatic Mode)
    Current ranges (applied)
    Current resolution at each range (applied)
    1.57 nA, 47 fA, 47 nA, 1.57 fA, 47 pA, 1.57 pA
    DC accuracy (current, applied)
    ±0.2% of setting; ±0.05% of range
    DAC output (current)
    16 bits
    Power Amplifier (Counter Electrode Amplifier)
    Output current
    ±1.5 mA (maximum)
    Short circuit current limit
    all ranges: 10 mA
    Compliance voltage
    Bandwidth
    >30 kHz (on fastest speed setting)
    Noise and ripple
    undetermined
    Slew rate/rise time
    800 V/ms (galvanostatic mode, on fastest speed setting), 180 V/ms (on fastest speed setting)
    Electrometer (Reference Electrode Amplifier)
    Input impedance
    >10¹³ in parallel with <10 pF
    Input current
    6 fA leakage/bias current typical, <100 fA max at 25°C
    CMRR
    >73 dB, 0 - 100 Hz, >60 dB ≤1 kHz, >39 dB ≤10 kHz
    Electrometer bandwidth
    > 800 kHz (3 dB)
    Measured Potential
    Potential ranges (measured)
    Potential resolution at each range (measured)
    250 µV per ADC bit
    DC accuracy (potential, measured)
    ±0.2% of setting; ±0.05% of range
    ADC output
    16 bits
    Filters (for DC Experiments)
    1 kHz, 12 Hz
    Applied Potential (Potentiostatic Mode)
    Potential ranges (applied)
    Potential resolution at each range (applied)
    250 µV per DAC bit
    DC accuracy (potential, applied)
    ±0.2% of setting; ±0.05% of range
    DAC output (potential)
    16 bits
    CV sweep rate (maximum)
    Data Acquisition (for DC Experiments)
    Clock resolution
    500 ns (minimum time base)
    Point interval
    Synchronization
    Simultaneous current and potential input
    Raw point total
    <10 million per experiment
    Electrochemical Impedance Spectroscopy (EIS)
    EIS capable
    EIS frequency range
    EIS frequency resolution
    N/A
    EIS frequency stability
    N/A
    Modes
    N/A
    Voltage excitation setpoint
    N/A
    Current excitation setpoint
    N/A
    Frequency sweeping
    N/A
    EIS accuracy
    N/A
    Rotator Control Connections
    Rotator connector A
    N/A
    Rotator connector B
    4-pin connector includes chassis ground, rotator enable output signal (+15 V tolerant), analog signal ground (DC Common), and analog rotation rate control output signal
    Rate control signal
    ±10 V
    Digital enable signal
    Open drain with 4.7 kΩ pull up to +4 V (TTL compatible), open drain (TTL compatible)
    Accessories
    Dummy cell
    External dummy cell included
    Cell cable
    HD-15 male connector to multiple banana plugs via shielded coaxial cables (included)
    Auxiliary Connections
    Connector C
    N/A
    Trigger input
    N/A
    Trigger output
    N/A
    Potential (E1) output
    N/A
    Current (I1) output
    N/A
    Potential (E2) output
    N/A
    Current (I2) output
    N/A
    Auxiliary analog input
    N/A
    Auxiliary analog output
    N/A
    WK1 input
    N/A
    WK2 input
    N/A
    General
    Power input
    5.0 VDC, 2 A (low voltage DC device)
    Power supply input
    100 to 240 VAC, 0.5 A, 50 to 60 Hz
    Power supply output
    5 VDC, 2.0 A Power supply (included) has a C14 type input connector
    Power cord
    Various international cables sold separately (C13 type)
    LED indicators
    Power, USB/wireless connection, status, and overload
    Instrument dimensions
    55 × 170 × 130 mm (2.17 × 6.69 × 5.12 in)
    Workstation shipping dimensions
    305 × 254 × 102 mm (12 × 10 × 4 in)
    Instrument weight
    0.6 kg (1.25 lb)
    Workstation shipping weight
    1.8 kg (4 lb)
    Temperature range
    10°C - 40°C
    Humidity range
    80% RH maximum, non-condensing
    Communication
    Interface
    Wireless capable