WaveNeuro Two FSCV Workstation System Bundle, with NI Interface

Part Number
[NEC-WN-TWO-P]

The WaveNeuro Two Fast Scan Cyclic Voltammetry (FSCV) Potentiostat System Plus Bundle is a unique electrochemical instrument you will not find from other traditional electrochemical suppliers.  We are excited to bring high quality, regularly available, and uniquely designed neuroelectrochemical research products to you.  Designed by FSCV scientists for FSCV scientists, the WaveNeuro is well-designed, of high quality construction, and supported by a company dedicated to supporting the instrument, as well as you the researcher.  The WaveNeuro seeks to fill the gap that exists for commercial fast-scan cyclic voltammetry (FSCV) systems.  The system provides you with the following:

  • Systems and accessories are in stock and ready to ship
  • Novel design integrates “breakout box”, potentiostat, filters, and data acquisition connectors into one box
  • Intuitive and clearly-labeled connectors
  • Behavioral input mapping to digital and analog input/output connections included
  • Designed for use with Pine Research modular headstage cable design
  • The WaveNeuro Two model is a two working electrode (headstage) channel system, for simultaneous use at two electrodes at the same time (same or different waveforms)
Product Bundle

This is a product bundle, meaning several compatible products are included together. View the individual bundle products in the tab below.

Login to View Prices

Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.

The WaveNeuro Two Fast Scan Cyclic Voltammetry (FSCV) Potentiostat System Plus Bundle is a unique electrochemical instrument you will not find from other traditional electrochemical suppliers.  We are excited to bring high quality, regularly available, and uniquely designed neuroelectrochemical research products to you.  Designed by FSCV scientists for FSCV scientists, the WaveNeuro is well-designed, of high quality construction, and supported by a company dedicated to supporting the instrument, as well as you the researcher.  The WaveNeuro seeks to fill the gap that exists for commercial fast-scan cyclic voltammetry (FSCV) systems.  The system provides you with the following:

  • Systems and accessories are in stock and ready to ship
  • Novel design integrates “breakout box”, potentiostat, filters, and data acquisition connectors into one box
  • Intuitive and clearly-labeled connectors
  • Behavioral input mapping to digital and analog input/output connections included
  • Designed for use with Pine Research modular headstage cable design
  • The WaveNeuro Two model is a two working electrode (headstage) channel system, for simultaneous use at two electrodes at the same time (same or different waveforms)
Important
More Detail
Bundle Products
Specifications
Pine Research Does Not Provide Software for the WaveNeuro

The WaveNeuro series FSCV potentiostat systems are interfaced to a PC via National Instruments PCIe-6363 interface. The system was designed for use with HDCV Software, which is available for purchase from the University of North Carolina at Chapel Hill. Pine Research does not maintain, sell, or distribute HDCV Software.

Demon Voltammetry Software Compatibility

Developed by the Sara Jones (Wake Forest University) laboratory, Demon Voltammetry has been interfaced with Pine Research WaveNeuro series systems. Doing so requries a special "One NI Board" version of the software. Interested customers should contact the Sara Jones lab for details on how to acquire such a version of the software. Pine Research does not maintain or distribute Demon Voltammetry and cannot provide software support when used with a WaveNeuro system.

FSCV Instrumentation Journal Article

R.M. Wightman et. al. have well-described FSCV instrumentation, including working driven headstages. Pine Research has based the design of the WaveNeuro FSCV systems and accessories in a similar manner as that which they decribe.

Working Driven Headstage

Pine Research currently offers working driven headstage amplifiers. In a working driven system, the reference electrode is grounded. The FSCV potential waveform (ramp) is connected to the non-inverting input of the operational amplifier, while the working electrode is connected to the inverting input. In this arrangement, the voltage at the microelectrode will follow the ramp applied to the inverting input. This means that even when no electrodes are connected (connector just in air) to the headstage amplifier cable, which is connected to the WaveNeuro, HDCV will show a current response that follows the applied waveform, which is the expected behavior for a working driven headstage.

The WaveNeuro Two Fast Scan Cyclic Voltammetry (FSCV) Potentiostat Plus Bundle is a unique electrochemical instrument you will not find from other traditional electrochemical suppliers.  We are excited to bring high quality, regularly available, and uniquely designed neuroelectrochemical research products to you.  Designed by FSCV scientists for FSCV scientists, the WaveNeuro Two is well-designed, of high quality construction, and supported by a company dedicated to supporting the instrument, as well as you the researcher.  The WaveNeuro Two seeks to fill the gap that exists for commercial fast-scan cyclic voltammetry (FSCV) systems.

The WaveNeuro Two Potentiostat was designed for the scientist (neuroscientist, psychologist, physician, chemist, biologist, etc.) who seeks to study the link between the brain chemistry of electroactive species (such as monoamines, catecholamines like dopamine and serotonin, oxygen, peroxide, etc.) and physiology (such as structure, function, disease, neural transmission, etc.) and behavior (such as addiction, impulsivity, decision-making, etc.).  Microdialysis, still a technique used in the field, can provide high spatial resolution for detection of these chemical species but offers poor temporal resolution.  FSCV, as a technique, provides both high spatial and high temporal resolution.  Coupled with carbon fiber microelectrodes, FSCV provides a well-established platform for in-vivo and in-vitro experimentation.

Traditionally, the products and instrumentation required to perform FSCV have only been available through scientific connections with developing laboratories.  As the technique has grown in popularity, due in part to its relative ease of use, the availability of instrumentation has not followed the same trend.  We are excited to bring such FSCV instrumentation to the market, thereby providing the robust technical, service, and sales support you have come to expect in the field of research instrumentation.

The WaveNeuro Two seeks to fill the gap that exists for commercial FSCV systems by providing systems with many novel features, such as:

  • Products are in stock and ready to ship! Who can wait 8 weeks or more when your research productivity is on the line?
  • A system that breaks from the past, with an overall updated design, including: a "breakout box" built into and included with the WaveNeuro, intuitive and clearly-labeled connectors, in a small dimensional footprint.
  • Built for flexibility - includes behavioral input mapping to digital and analog input/output connections.
  • Designed with Pine Research modular headstage cable design, preventing that "pile of unknown headstage/cables" that so many labs make over time.
  • Now evolved design to accommodate two working electrode (headstage) channels simultaneously!  Twice the data per experiment for a nominal increase in price.  Expand your productivity.
WaveNeuro Two FSCV Workstation System Bundle, with NI Interface is sold as a product bundle. Product bundles combine multiple products into one purchase. For details or to purchase additional items, visit the product page for any item in the bundle below.
Qty
Image
Product Name
Part #
1
WaveNeuro One FSCV System
AF01FSCV1
1
WaveNeuro Dual Channel Adapter (DCA)
AB01HC0601-LF
1
Placeholder Image
WaveNeuro Dummy Cell
AB01DUM4-LF
2
Headstage Amplifier Cable – 24″ Length
RRHC0124-T
2
FSCV Headstage Amplifier (5 megaohm/200 nA/V)
AC01HS1
2
Microelectrode-Headstage Coupler – 1.5″ Length
AC01HC0315-5
1
Placeholder Image
National Instruments PCIe-6363 Data Acquisition Interface Board
EANPCIE6363
2
National Instruments 68-pin DSUB to 68-pin VHDCI Cable
EWCP6102
1
Power Cords
POWER-CORD
WaveNeuro Two FSCV Workstation System Bundle, with NI Interface is sold as a product bundle. The data below aggregates the specifications for each product contained within the bundle..
WaveNeuro Two FSCV Workstation System Bundle, with NI Interface
Product Bundles
Product bundle
Bundle application
Fast-Scan Cyclic Voltammetry (FSCV)
Bundled electrochemical workstation
National Instruments 68-pin DSUB to 68-pin VHDCI Cable
Cables
Cable type
Interface, Signal
Cable terminal A type
Plug, National Instruments 68-pin
Cable terminal B type
Plug, National Instruments VHDCI 68-pin
Cable length
2 m
Cable color
Black
Cable instrument compatibility
CBP Bipotentiostat, WaveNeuro series FSCV electrochemical workstation
Power Cords