• Product Search
    Enter a part number or product name to perform a quick search of results with your search term...
    Search Term:
    Results
    • Cart

    WaveNeuro Four FSCV Workstation System Bundle, with 4-Channel Headstage, with NI Interface

    Part Number
    [NEC-WN-FOUR-P-4HS]

    The WaveNeuro Four Multichannel Fast Scan Cyclic Voltammetry (FSCV) Potentiostat System Plus Bundle with 4-Channel Headstage Kit is a unique electrochemical instrument you will not find from other traditional electrochemical suppliers.  We are excited to bring high quality, regularly available, and uniquely designed neuroelectrochemical research products to you.  Designed by FSCV scientists for FSCV scientists, the WaveNeuro Four is well-designed, of high quality construction, and supported by a company dedicated to supporting the instrument, as well as you the researcher.  The WaveNeuro Four seeks to fill the gap that exists for commercial fast-scan cyclic voltammetry (FSCV) systems.

    Product Bundle
    This is a product bundle. Product bundles combine compatible products together for easier purchasing and confidence. You can view the bundles that include this product in the tab below.

    The WaveNeuro Four Multichannel Fast Scan Cyclic Voltammetry (FSCV) Potentiostat System Plus Bundle with 4-Channel Headstage Kit is a unique electrochemical instrument you will not find from other traditional electrochemical suppliers.  We are excited to bring high quality, regularly available, and uniquely designed neuroelectrochemical research products to you.  Designed by FSCV scientists for FSCV scientists, the WaveNeuro Four is well-designed, of high quality construction, and supported by a company dedicated to supporting the instrument, as well as you the researcher.  The WaveNeuro Four seeks to fill the gap that exists for commercial fast-scan cyclic voltammetry (FSCV) systems.

    Components below showing require a selection. Components showing are optional, and do not require a selection.

    Bundle Customizer

    Toggle each component below and make your selection. Once all required selections have been made, the total price and add to cart button will display at the end of the components list.

    Important
    More Detail
    Bundle Products
    Specifications
    Pine Research Does Not Provide Software for the WaveNeuro
    The WaveNeuro series FSCV potentiostat systems are interfaced to a PC via National Instruments PCIe-6363 interface. The system was designed for use with HDCV Software, which is available for purchase from the University of North Carolina at Chapel Hill. Pine Research does not maintain, sell, or distribute HDCV Software.
    Demon Voltammetry Software Compatibility
    Developed by the Sara Jones (Wake Forest University) laboratory, Demon Voltammetry has been interfaced with Pine Research WaveNeuro series systems. Doing so requries a special "One NI Board" version of the software. Interested customers should contact the Sara Jones lab for details on how to acquire such a version of the software. Pine Research does not maintain or distribute Demon Voltammetry and cannot provide software support when used with a WaveNeuro system.
    Working Driven Headstage
    Pine Research currently offers working driven headstage amplifiers. In a working driven system, the reference electrode is grounded. The FSCV potential waveform (ramp) is connected to the non-inverting input of the operational amplifier, while the working electrode is connected to the inverting input. In this arrangement, the voltage at the microelectrode will follow the ramp applied to the inverting input. This means that even when no electrodes are connected (connector just in air) to the headstage amplifier cable, which is connected to the WaveNeuro, HDCV will show a current response that follows the applied waveform, which is the expected behavior for a working driven headstage.
    FSCV Instrumentation Journal Article
    R.M. Wightman et. al. have well-described FSCV instrumentation, including working driven headstages. Pine Research has based the design of the WaveNeuro FSCV systems and accessories in a similar manner as that which they decribe.

    The WaveNeuro Four Fast Scan Cyclic Voltammetry (FSCV) Potentiostat Plus Bundle with Four Channel Headstage is a unique electrochemical instrument you will not find from other traditional electrochemical suppliers.  We are excited to bring high quality, regularly available, and uniquely designed neuroelectrochemical research products to you.  Designed by FSCV scientists for FSCV scientists, the WaveNeuro Four is well-designed, of high-quality construction, and supported by a company dedicated to supporting the instrument, as well as you the researcher.  The WaveNeuro Four seeks to fill the gap that exists for commercial multichannel fast-scan cyclic voltammetry (FSCV) systems.

    The WaveNeuro Four Multichannel Potentiostat was designed for the scientist (neuroscientist, psychologist, physician, chemist, biologist, etc.) who seeks to study the link between the brain chemistry of electroactive species (such as monoamines, catecholamines like dopamine and serotonin, oxygen, peroxide, etc.) and physiology (such as structure, function, disease, neural transmission, etc.) and behavior (such as addiction, impulsivity, decision-making, etc.).  Microdialysis, still a technique used in the field, can provide high spatial resolution for the detection of these chemical species but offers poor temporal resolution.  FSCV, as a technique, provides both high spatial and high temporal resolution.  Coupled with carbon fiber microelectrodes, FSCV provides a well-established platform for in-vivo and in-vitro experimentation.

    The WaveNeuro Four has been developed in response to more of the FSCV community who want to make simultaneous measurements.  The WaveNeuro Four is like the WaveNeuro One, however it can be used to apply up to four independent waveforms, simultaneously.  Perhaps you want to measure dopamine in several locations during a single experiment?  Perhaps you want to increase throughput and collect FSCV data in four different animals/tissues simultaneously?  With the WaveNeuro Four, we have made it possible - without having to custom order such a system for $30,000 and have to wait 8 - 12 months for delivery!  The WaveNeuro Four uses a single PCIe-6363 (like all WaveNeuro FSCV potentiostats) and is compatible with HDCV software.

    Traditionally, the products and instrumentation required to perform FSCV have only been available through scientific connections with developing laboratories.  As the technique has grown in popularity, due in part to its relative ease of use, the availability of instrumentation has not followed the same trend.  We are excited to bring such FSCV instrumentation to the market, thereby providing the robust technical, service, and sales support you have come to expect in the field of research instrumentation.

    The WaveNeuro Four seeks to fill the gap that exists for commercial FSCV systems by providing systems with many novel features, such as:

    • Products are in stock and ready to ship! Who can wait 8 weeks or more when your research productivity is on the line?
    • A system that breaks from the past, with an overall updated design, including: a "breakout box" built into and included with the WaveNeuro, intuitive and clearly-labeled connectors, in a small dimensional footprint.
    • Built for flexibility - includes behavioral input mapping to digital and analog input/output connections.
    • Designed with Pine Research modular headstage cable design, preventing that "pile of unknown headstage/cables" that so many labs make over time.
    • Now evolved design to accommodate FOUR working electrode (headstage) channels simultaneously, with a single headstage cable!  4x the data per experiment for a nominal increase in price. Expand your productivity.
    WaveNeuro Four FSCV Workstation System Bundle, with 4-Channel Headstage, with NI Interface is sold as a product bundle. Product bundles combine multiple products into one purchase. For details or to purchase additional items, visit the product page for any item in the bundle below.
    Qty
    Image
    Product Name
    Part #
    1
    WaveNeuro Four FSCV System
    AF01FSCV4
    2
    WaveNow Dummy Cell
    AB01DUM1-LF
    1
    Four-Channel Headstage Adapter for WaveNeuro Four
    AB01HC0701
    1
    Four-Channel FSCV Headstage Adapter
    AC01HS4
    1
    Four-Channel Headstage-to-Microelectrode Coupler Wire Assembly
    AC01HC0503
    1
    Four-Channel Headstage Cable
    RRHC0620
    1
    National Instruments PCIe-6363 Data Acquisition Interface Board
    EANPCIE6363
    2
    NI SHC68-68 EPM Interface Cable
    EWCP6102
    WaveNeuro Four FSCV Workstation System Bundle, with 4-Channel Headstage, with NI Interface is sold as a product bundle. The data below aggregates the specifications for each product contained within the bundle..
    WaveNeuro Four FSCV Workstation System Bundle, with 4-Channel Headstage, with NI Interface
    Product Bundles
    Product bundle
    Bundle includes
    Cables, Electrochemical workstation, Headstage amplifier, Interface board
    Bundle application
    Fast-Scan Cyclic Voltammetry (FSCV)