Corrosion Cell Kit Bundle, Complete OpenTop Cell Kit with Drain Valve, 15 mm RCE

Part Number
[RCE15-V]

Join the rest of the community that depends on Pine Research Instrumentation Rotating Cylinder Electrode systems.   Our 15 mm RCE electrode system is the trusted tool to perform corrosion analysis, namely screening of corrosion inhibitors.  Identifying and selecting all the required components of a complete RCE electrochemical corrosion screening system can be a daunting task.  We have helped ease that burden by organizing RCE bundle options with several options to suit your laboratory needs.

The RCE Bundle with Cell with Drain Valve is everything you need except an Electrochemical Workstation and MSR evo Electrode Rotator and features the 1 liter cell with drain valve.

Product Bundle

This is a product bundle, meaning several compatible products are included together. View the individual bundle products in the tab below.

Login to View Prices

Customers must be logged into their account to view prices. Not all regions provide pricing online. If you do not see prices, you can obtain them from the designated sales channel in your region.

Pricing Not Available Online - Contact Sales Channel

We are not able to provide online pricing for your account. Please contact Pine Research Instrumentation, Inc., who is your local sales channel, to obtain pricing or a quotation from your designated agent.

Join the rest of the community that depends on Pine Research Instrumentation Rotating Cylinder Electrode systems.   Our 15 mm RCE electrode system is the trusted tool to perform corrosion analysis, namely screening of corrosion inhibitors.  Identifying and selecting all the required components of a complete RCE electrochemical corrosion screening system can be a daunting task.  We have helped ease that burden by organizing RCE bundle options with several options to suit your laboratory needs.

The RCE Bundle with Cell with Drain Valve is everything you need except an Electrochemical Workstation and MSR evo Electrode Rotator and features the 1 liter cell with drain valve.

Join the rest of the community that depends on Pine Research Instrumentation Rotating Cylinder Electrode systems.   Our 15 mm RCE electrode system is the trusted tool to perform corrosion analysis, namely screening of corrosion inhibitors.  Identifying and selecting all the required components of a complete RCE electrochemical corrosion screening system can be a daunting task.  We have helped ease that burden by organizing RCE bundle options with several options to suit your laboratory needs.  A complete RCE system requires a potentiostat, electrode rotator, rotating cylinder electrode, cell with all accessories, counter electrode, reference electrode, and common accessories such as Luggin tubes and gas sparge/purge tubes. The corrosion cell included with this bundle is the 1 liter basic cell with drain valve, perfect for controlling solution temperature on a hot plate.

The 15 mm OD Rotating Cylinder Electrode (RCE) system features a number of improvements over previous designs which will assist you in your high velocity (high shear) corrosion testing.   The larger 15 mm diameter gives you more wall shear at the cylinder surface at a given rotation rate (as compared to the traditional 12 mm OD design).

Insulation. All shaft components are fabricated from a chemically resistant polymer (PEEK) to protect the shaft from corrosive attack during testing. At elevated temperatures, this polymer has good mechanical stability as compared to the traditional PTFE-based 12 mm OD design. One Liter Cell. With an overall one liter capacity, the cell features a removable lid with six flexible side ports. You can equip your cell with a variety of accessories (condenser, pH measurement, thermowell, each sold separately) while still having enough ports for the reference and counter electrode. Cells with drain valves and water jackets are also available. Alignment. The standard RCE glass cell features a special recess in the bottom of the cell into which the lower end of the RCE shaft is inserted. This recess provides a guide for aligning the shaft along the center line of the cell. Purging. A dual port purge accessory is included with the cell which permits you to sparge the solution and/or blanket the solution with a purge gas. In addition, the gas-purged bearing assembly, through which the rotating shaft enters the cell, has a separate purge port so that you can maintain a positive purging pressure within the internal space of the bearing itself. Specimens. The lower end of the electrode shaft accepts 15 mm OD x 6.4 mm tall replaceable cylinder inserts. The nominal cylindrical surface area exposed to the solution is 3.0 square centimeters. Standard cylinder inserts fabricated from a variety of steel materials are offered by Pine Research. Custom inserts fabricated from other materials are available upon request. Alternately, cylinder inserts with the appropriate dimensions may be fabricated by the customer. Contact. Reliable electrical contact between the shaft and the replaceable cylinder insert is accomplished using a spring-loaded ball plunger which pushes against the inside diameter of the cylinder insert.
Corrosion Cell Kit Bundle, Complete OpenTop Cell Kit with Drain Valve, 15 mm RCE is sold as a product bundle. Product bundles combine multiple products into one purchase. For details or to purchase additional items, visit the product page for any item in the bundle below.
Qty
Image
Product Name
Part #
1
Rotating Cylinder Cell Kit, OpenTop, 15 mm OD RCE, Drain Valve
AFCELL8U
1
E9 Series Precision RCE Shaft 15 mm Cylinders
AFE9MBA
1
Bearing Assembly, Gas-Purged, for AFE6MB/AFE9MBA Shaft, PEEK, with 24/25 Taper
AC01TPA6M
1
Counter Electrode Assembly, Graphite (C), 24/25
AFCTR3
1
Luggin Tube for OpenTop RCE Cells
RRPG031
1
Dual Port Gas Inlet for 15 mm OD RCE Cells, 24/25 Taper
RRPG034
Corrosion Cell Kit Bundle, Complete OpenTop Cell Kit with Drain Valve, 15 mm RCE is sold as a product bundle. The data below aggregates the specifications for each product contained within the bundle.
Corrosion Cell Kit Bundle, Complete OpenTop Cell Kit with Drain Valve, 15 mm RCE
Product Bundles
Product bundle
Bundle application
Corrosion, Rotating Cylinder (RCE)
E9 Series Precision RCE Shaft 15 mm Cylinders
Working Electrodes
General
Electrode series
Thermal stability range
10°C - 80°C
Rotating Electrodes
Maximum rotation rate
Cylinder Electrodes
Cylinder series compatibility
AFE9C150 (15 mm OD)
Electrode Rotator
Compatibility
Compatible electrode tips
Applications
Rotating application
Electrode Shafts
Shaft length (overall)
259 mm (10.2 in)
Shaft shroud diameter
Shaft shroud length
152 mm
Shaft shroud material

End User Certification of Exported Goods

All orders from Pine Research Instrumentation that are destined to be exported for use outside of the United States requires that the parties involved (end-user, intermediate consignee, and ultimate consignee) disclose the parties involved in the transaction. By signing this form, parties acknowledge having read and understood export restrictions and requirements.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Exports Compliance Statement

Please carefully read this statement. Acknowledge you have read and understood the statment below to proceed.
As dictated by United States export control law, this End Use Certificate certifies the following regarding the good being imported or exported:
  1. Will not be imported, re-exported or transferred to be used in the design, development, production, stockpiling, or use of chemical or biological weapons and their precursors.
  2. Will not be imported, re-exported or transferred to be used in the design, development, production, stockpiling, or use of missiles, rocket systems or unmanned air vehicles of any range or payload. “Rocket systems” include, but are not limited to, ballistic missile systems, space launch vehicles, and sounding rockets. “Unmanned air vehicles” include, but are not limited to, cruise missile systems, target drones and reconnaissance drones.
  3. Product and/or replicas ("replicas" refers to items produced abroad on physical examination of the item originally exported, matching it in all critical design and performance parameters) thereof will not be used (either directly or indirectly) in sensitive nuclear end-uses, as follows:
    1. Nuclear explosive activities: Nuclear explosive activities, including research on or development, design, manufacture, construction, testing or maintenance of any nuclear explosive device, or components or subsystems of such a device.
    2. Unsafeguarded nuclear activities: Activities including research on or development, design, manufacture construction, operation, or maintenance of any nuclear reactor, critical facility, facility for the fabrication of nuclear fuel, facility for the conversion of nuclear material from one chemical form to another, or separate storage installation, where there is no obligation to accept International Atomic Energy Agency (IAEA) safeguards at the relevant facility or installation when it contains any source or special fissionable material (regardless of whether or not it contains such material at the time of export), or where any such obligation is not met.
    3. Safeguarded and unsafeguarded nuclear activities: Safeguarded and unsafeguarded nuclear fuel cycle activities, including research on or development, design, manufacture, construction, operation or maintenance of any of the following facilities, or components for such facilities for the:
      1. Facilities for the chemical processing of irradiated special nuclear or source material;
      2. Facilities for the production of heavy water;
      3. Facilities for the separation of isotopes of source and special nuclear material; or
      4. Facilities for the fabrication of nuclear reactor fuel containing plutonium.
  4. The goods will not be imported, re-exported or transferred to be used in the design, development, production, construction, support, or maintenance of a maritime nuclear propulsion project; including any machinery, devices, components or equipment specifically developed or designed for use in such plants or facilities.
  5. Will not be imported, re-exported or transferred to be used in crime control and detection commodities and end-uses.
  6. Will not be imported, re-exported or transferred to destinations embargoed by the U.S. government (unless deminimus provisions apply).
  7. Will not be imported, re-exported or transferred to entities listed on U.S. government denial lists: U.S. Department of Commerce Denied Persons List, Treasury Department Specially Designated Nationals and Blocked Persons Lists, State Department Debarment List, and State Department Parties of Proliferation Concern.
  8. Will not be imported, re-exported or transfered for use by the end-users listed on the Entity List, Supplement No. 4, Part 744 of the EAR without approval from the U.S. Department of Commerce or the Pine Instrument Company International Dept.
  9. Will not be imported, re-exported or transferred to be used by persons on the Unverified List as published by the U.S. Department of Commerce Bureau of Industry and Security.
  10. Written Authorization will be obtained from the Bureau of Industry and Security prior to re-exporting the items or technology, unless they would be eligible for export from the United States to the new country of destination under U.S. export law.
  11. Will not be used, sold, resold, delivered or transferred, directly or indirectly, contrary to U.S. export regulations.
  12. Will not be imported or re-exported for use by or for by persons who commit, threaten to commit or support terrorism. The term terrorism means an activity that:
    1. Involves a violent act or an act dangerous to human life, property, or infrastructure; and
    2. Appears to be intended:
      1. to intimidate or coerce a civilian population;
      2. to influence the policy of a government by intimidation or coercion; or
      3. to affect the conduct of a government by mass destruction, assassination, kidnapping or hostage taking.

Login
Register
Lost Password

Please enter your username (email address) and password below.

Confirm Logout

Are you sure you want to log out?

Request a Quote for this Cart

Below is the billing data we have on file. These details will be used on your quotation, so please update them here if you require any changes. Changing any details here updates them for your account.